International Journal of Environmental Research and Public Health (MDPI)
2004 | 525,942,120 words
The International Journal of Environmental Research and Public Health (IJERPH) is a peer-reviewed, open-access, transdisciplinary journal published by MDPI. It publishes monthly research covering various areas including global health, behavioral and mental health, environmental science, disease prevention, and health-related quality of life. Affili...
Trabecular Bone Assessment Using Magnetic-Resonance Imaging: A Pilot Study
Lauren Bohner
Department of Cranio-Maxillofacial Surgery, University Hospital Muenster, 48149 Muenster, Germany
Pedro Tortamano
Department of Prosthodontics, School of Dentistry, University of São Paulo, São Paulo 0508-000, Brazil
Norbert Meier
Institute of Clinical Radiology, University Clinics Muenster, 48149 Muenster, Germany
Felix Gremse
Department of Experimental Molecular Imaging, Helmholtz Institute, RWTH Aachen University, 52074 Aachen, Germany
Johannes Kleinheinz
Department of Cranio-Maxillofacial Surgery, University Hospital Muenster, 48149 Muenster, Germany
Marcel Hanisch
Department of Cranio-Maxillofacial Surgery, University Hospital Muenster, 48149 Muenster, Germany
Download the PDF file of the original publication
Year: 2020 | Doi: 10.3390/ijerph17249282
Copyright (license): Creative Commons Attribution 4.0 International (CC BY 4.0) license.
[[[ p. 1 ]]]
[Find the meaning and references behind the names: Brazil, Choice, Doi, Aim, Pilot, Norbert, Marcel, Dental, Johannes, Int, Set, Hospital, Present, Peri, Time, Safe, December, Germany, Size, Pearson, High, Far, Sense, Pedro, Mri, Cone, Meier, Hanisch, Echo, Fixed, November, Play, Given, Jaw, Due, Role, Lauren, Bone, Paulo, Study, Strong, Beam, Tel, Spin, Quality, Felix]
International Journal of Environmental Research and Public Health Article Trabecular Bone Assessment Using Magnetic-Resonance Imaging: A Pilot Study Lauren Bohner 1,2, * , Pedro Tortamano 2 , Norbert Meier 3 , Felix Gremse 4 , Johannes Kleinheinz 1 and Marcel Hanisch 1 1 Department of Cranio-Maxillofacial Surgery, University Hospital Muenster, 48149 Muenster, Germany; johannes.kleinheinz@ukmuenster.de (J.K.); marcel.hanisch@ukmuenster.de (M.H.) 2 Department of Prosthodontics, School of Dentistry, University of S ã o Paulo, S ã o Paulo 0508-000, Brazil; tortamano@usp.br 3 Institute of Clinical Radiology, University Clinics Muenster, 48149 Muenster, Germany; norbert.meier@ukmuenster.de 4 Department of Experimental Molecular Imaging, Helmholtz Institute, RWTH Aachen University, 52074 Aachen, Germany; fgremse@ukaachen.de * Correspondence: lauren.bohner@ukmuenster.de; Tel.: + 49-25183-47004 Received: 25 November 2020; Accepted: 9 December 2020; Published: 11 December 2020 Abstract: The aim of this study was to assess trabecular bone morphology via magnetic-resonance imaging (MRI) using microcomputed tomography ( µ CT) as the control group. Porcine bone samples were scanned with T 1-weighted turbo spin echo sequence imaging, using TR 25 ms, TE 3.5 ms, FOV 100 × 100 × 90, voxel size 0.22 × 0.22 × 0.50 mm, and scan time of 11:18 µ CT was used as the control group with 80 kV, 125 mA, and a voxel size of 16 µ m. The trabecular bone was segmented on the basis of a reference threshold value and morphological parameters. Bone volume (BV), Bone-volume fraction (BvTv), Bone specific surface (BsBv), trabecular thickness (TbTh), and trabecular separation (TbSp) were evaluated. Paired t -test and Pearson correlation test were performed at p = 0.05. MRI overestimated BV, BvTv, TbTh, and TbSp values. BsBv was the only parameter that was underestimated by MRI. High statistical correlation (r = 0.826; p < 0.05) was found for BV measurements. Within the limitations of this study, MRI overestimated trabecular bone parameters, but with a statistically significant fixed linear o ff set Keywords: dental implants; magnetic-resonance imaging; microCT 1. Introduction As far as dental-implant planning is concerned, special attention is given to trabecular-bone assessment. Although adequate bone volume is a requisite for peri-implant health, it has been proven that bone quality may also play an important role in dental-implant outcomes. According to the classification of Lekholm and Zarb [ 1 ], the jaw bone may either present cortical bone with di ff erent thickness or trabecular bone with variable microarchitecture. In this sense, recent studies showed that cortical thickness influences the primary stability of dental implants [ 2 , 3 ]. However, successful implant treatment is related not only to bone volume, but also to the micromorphology of trabeculae, and how they are arranged and connected to each other [ 4 ]. Cone-beam computed tomography (CBCT) is the method of choice for bone assessment This technique has the advantage of three-dimensional (3 D) reconstruction with su ffi cient spatial resolution compared to conventional methods [ 5 – 7 ]. However, CBCT indication is limited due to its ionizing nature [ 8 ]. Thus, in order to o ff er a safe method for bone assessment, the use of alternative techniques, such as magnetic-resonance imaging (MRI), was extensively explored [ 9 – 13 ]. Int. J. Environ. Res. Public Health 2020 , 17 , 9282; doi:10.3390 / ijerph 17249282 www.mdpi.com / journal / ijerph
[[[ p. 2 ]]]
[Find the meaning and references behind the names: Level, Gold, Local, Belgium, Standard, Body, Prior, Ribs, Gray, Channel, Power, Cases, Tool, Seem, Voi, Oral, Foot, Philips, Middle, Gel, Mean, Sample, Table, Apex, Still, Image, Weeks, Bath, Bright, Marker, Short]
Int. J. Environ. Res. Public Health 2020 , 17 , 9282 2 of 7 The use of MRI for implant planning and monitoring was also investigated [ 11 , 12 , 14 – 22 ]. It shows potential to evaluate bone dimension and visualize bone defects prior to the implant placement [ 11 , 22 ]. Although artifacts may occur due to the presence of oral tissue and dental materials, they seem to be localized and, in several cases, negligible for diagnosis [ 23 ]. Moreover, the medical literature showed its potential to determine bone quality of osteoporotic patients [ 24 ]. However, the assessment of bone quality for dental-implant planning has still not been reported. The aim of this study was to assess trabecular-bone morphology through MRI, using microcomputed tomography ( µ CT) as the control group 2. Materials and Methods Porcine ribs acquired from a local butchery for a previous study [ 25 ] were used in this study Samples were scanned with MRI, and µ CT scans were used as reference values. The study was approved by the Ethics Committee of Hospital University Münster (protocol number 2017-629-f-N) A pilot study was performed, and sample size was calculated using GPower 3.1 (University of Düsseldorf) [ 26 ]. Considering a two-tailed t -test, with a power of 80% and significance level at 0.05, at least 7 samples were required to detect a mean di ff erence of 0.26 ± 0.19 mm 3 (mean ± standard deviation) in trabecular-bone volume measured by µ CT and MRI. In order to control intrarater reliability, measurements were performed twice by the same examiner Briefly, porcine ribs were prepared by removing soft tissue and periosteum, and then sectioned into bone pieces measuring approximately 3 cm in width. On each sample, a conical perforation was prepared according to the manufacturer instructions using dental-implant surgical drills (Straumann) For this study, dental implants were not placed. Instead, the perforation was used as a reference marker for the determination of the measurement site. All samples were immersed into a 3.5% formaldehyde bath 4 weeks prior to the study As a gold-standard control, each bone sample was scanned with µ CT (SkyScan 1272; Bruker, Kontich, Belgium) with 80 kV, 125 mA, and a voxel size of 16 µ m. For MRI scanning, each sample was inserted into a plastic conical container filled with ultrasound gel. T 1-weighted turbo spin echo sequence imaging was performed using a whole-body 3 T magnetic-resonance system (Philips, Healthcare System) with 8-channel SENSE-foot / Ankle coil, TR 25 ms, TE 3.5 ms, FOV 100 × 100 × 90, voxel size 0.22 × 0.22 × 0.50 mm, and a scan time of 11:18. Tissue with short T 2 relaxation times was presented as bright values Trabecular-bone segmentation and assessment were performed using imaging software (Imalytics Preclinical, Gremse-IT GmbH) [ 27 ]. First, images were reoriented with the center of perforation on a three-coordinate axis (x,y,z) as reference. A center marker was set at the apex region exactly 10 mm from the middle-diameter of the perforation. This marker was used as reference to define the center of the volume of interest (VOI). Using an automatic tool, a conical VOI measuring 5 × 10 mm (diameter × height) was defined (Figure 1 ). In order to define the gray-scale value that separated the trabecular bone from the medullary space, a mean threshold value was calculated for each image. Trabecular-bone segmentation used this threshold value as reference, and distance mapping was employed to refine the segmentation on the basis of morphological features (Figure 2 ). Table 1 indicates the bone parameters calculated in this study.
[[[ p. 3 ]]]
[Find the meaning and references behind the names: Ibm, Left, Lines, Data, Under, Shapiro, Green, Blue, Right, Wilk]
Int. J. Environ. Res. Public Health 2020 , 17 , 9282 3 of 7 Int. J. Environ. Res. Public Health 2020 , 17 , x 2 of 7 The use of MRI for implant planning and monitoring was also investigated [11,12,14–22]. It shows potential to evaluate bone dimension and visualize bone defects prior to the implant placement [11,22]. Although artifacts may occur due to the presence of oral tissue and dental materials, they seem to be localized and, in several cases, negligible for diagnosis [23]. Moreover, the medical literature showed its potential to determine bone quality of osteoporotic patients [24]. However, the assessment of bone quality for dental-implant planning has still not been reported. The aim of this study was to assess trabecular-bone morphology through MRI, using microcomputed tomography (µCT) as the control group. 2. Materials and Methods Porcine ribs acquired from a local butchery for a previous study [25] were used in this study. Samples were scanned with MRI, and µCT scans were used as reference values. The study was approved by the Ethics Committee of Hospital University Münster (protocol number 2017-629-f-N). A pilot study was performed, and sample size was calculated using GPower 3.1 (University of Düsseldorf) [26]. Considering a two-tailed t -test, with a power of 80% and significance level at 0.05, at least 7 samples were required to detect a mean difference of 0.26 ± 0.19 mm 3 (mean ± standard deviation) in trabecular-bone volume measured by µCT and MRI. In order to control intrarater reliability, measurements were performed twice by the same examiner. Briefly, porcine ribs were prepared by removing soft tissue and periosteum, and then sectioned into bone pieces measuring approximately 3 cm in width. On each sample, a conical perforation was prepared according to the manufacturer instructions using dental-implant surgical drills (Straumann). For this study, dental implants were not placed. Instead, the perforation was used as a reference marker for the determination of the measurement site. All samples were immersed into a 3.5% formaldehyde bath 4 weeks prior to the study. As a gold-standard control, each bone sample was scanned with µCT (SkyScan 1272; Bruker, Kontich, Belgium) with 80 kV, 125 mA, and a voxel size of 16 µm. For MRI scanning, each sample was inserted into a plastic conical container filled with ultrasound gel. T 1-weighted turbo spin echo sequence imaging was performed using a whole-body 3 T magnetic-resonance system (Philips, Healthcare System) with 8-channel SENSE-foot/Ankle coil, TR 25 ms, TE 3.5 ms, FOV 100 × 100 × 90, voxel size 0.22 × 0.22 × 0.50 mm, and a scan time of 11:18. Tissue with short T 2 relaxation times was presented as bright values. Trabecular-bone segmentation and assessment were performed using imaging software (Imalytics Preclinical, Gremse-IT GmbH) [27]. First, images were reoriented with the center of perforation on a three-coordinate axis (x,y,z) as reference. A center marker was set at the apex region exactly 10 mm from the middle-diameter of the perforation. This marker was used as reference to define the center of the volume of interest (VOI). Using an automatic tool, a conical VOI measuring 5 × 10 mm (diameter × height) was defined (Figure 1). Figure 1. Determination of volume of interest (VOI). ( a ) From right to left: Axial, coronal, and sagittal cuts of microcomputed tomography ( µ CT) images. ( b ) Using reference lines, perforation midcenter was determined. and VOI was segmented Int. J. Environ. Res. Public Health 2020 , 17 , x 3 of 7 Figure 1. Determination of volume of interest (VOI). ( a ) From right to left: Axial, coronal, and sagittal cuts of microcomputed tomography (µCT) images. ( b ) Using reference lines, perforation midcenter was determined. and VOI was segmented In order to define the gray-scale value that separated the trabecular bone from the medullary space, a mean threshold value was calculated for each image. Trabecular-bone segmentation used this threshold value as reference, and distance mapping was employed to refine the segmentation on the basis of morphological features (Figure 2). Table 1 indicates the bone parameters calculated in this study. Figure 2. Segmentation of trabecular bone Green and blue regions represent trabecular bone with ( a ) µCT segmentation and ( b ) magnetic-resonance-imaging (MRI) segmentation, respectively Table 1. Bone measurement parameters. Measurement Abbreviation Measurement Unit Description Trabecular bone volume BV mm 3 Trabecular bone volume at VOI, determined by gray values above threshold value Total bone volume TV mm 3 Total bone volume (VOI) Trabecular volume fraction BvTv % Ratio between trabecular and total bone volume Bone specific surface BsBv 1/cm Bone surface to bone volume ratio Trabecular thickness TbTh cm Trabecular bone thickness determined by distance between bone surface above threshold value Trabecular separation TbSp cm Mean distance between trabeculae, determined by gray values under threshold value Statistical analysis was performed using SPSS 0.26 software (IBM, Armonk, NY, USA) and reviewed by an independent statistician. Data normality was evaluated by Shapiro–Wilk test, and intrareader reliability was assessed using Cronbach’s test. A two-tailed paired t -test was used to compare the mean values measured by µCT and MRI, whereas the relation between groups was assessed by linear regression and Pearson’s correlation test. The statistical-significance level was considered at p ≤ 0.05. 3. Results Figure 2. Segmentation of trabecular bone. Green and blue regions represent trabecular bone with ( a ) µ CT segmentation and ( b ) magnetic-resonance-imaging (MRI) segmentation, respectively Table 1. Bone measurement parameters Measurement Abbreviation Measurement Unit Description Trabecular bone volume BV mm 3 Trabecular bone volume at VOI, determined by gray values above threshold value Total bone volume TV mm 3 Total bone volume (VOI) Trabecular volume fraction BvTv % Ratio between trabecular and total bone volume Bone specific surface BsBv 1 / cm Bone surface to bone volume ratio Trabecular thickness TbTh cm Trabecular bone thickness determined by distance between bone surface above threshold value Trabecular separation TbSp cm Mean distance between trabeculae, determined by gray values under threshold value
[[[ p. 4 ]]]
[Find the meaning and references behind the names: Reader, Sup, Inf, Show, General]
Int. J. Environ. Res. Public Health 2020 , 17 , 9282 4 of 7 Statistical analysis was performed using SPSS 0.26 software (IBM, Armonk, NY, USA) and reviewed by an independent statistician. Data normality was evaluated by Shapiro–Wilk test, and intrareader reliability was assessed using Cronbach’s test. A two-tailed paired t -test was used to compare the mean values measured by µ CT and MRI, whereas the relation between groups was assessed by linear regression and Pearson’s correlation test. The statistical-significance level was considered at p ≤ 0.05 3. Results Data presented adherence to Gaussian distribution, and were therefore described by mean and standard deviation. Intraclass reader reliability was high (0.96; p < 0.05). Tables 2 and 3 show the statistical analysis Table 2. Descriptive data of bone measurements acquired by microcomputed tomography ( µ CT) and magnetic-resonance imaging (MRI) Bone Measurements Imaging Device Mean ± SD BV (mm 3 ) µ CT 0.51 ± 0.22 MRI 0.82 ± 0.28 * BvTv (%) µ CT 29.48 ± 7.95 MRI 48.86 ± 11.66 * BsBv (1 / cm) µ CT 146.23 ± 42.95 MRI 30.06 ± 8.50 * TbTh (cm) µ CT 0.25 ± 0.07 MRI 1.28 ± 0.89 * TbSp (cm) µ CT 0.58 ± 0.07 MRI 1.19 ± 0.21 * * statistically significant di ff erence at p ≤ 0.05 Table 3. Statistical analysis Paired T -Test Pearson Correlation Bone Measurements t -Value df 95% CI r p Value Inf Sup BV − 5.8 6 − 0.46 − 0.189 0.826 0.01 BvTv − 4.49 6 − 29.92 − 8.81 0.274 0.27 BsBv 7.93 7 81.53 150.80 0.083 0.43 TbTh − 3.17 6 − 1.82 − 0.23 0.522 0.11 TbSp − 8.45 6 − 0.79 − 0.43 0.464 0.14 In general, MRI overestimated trabecular-bone parameters in comparison to µ CT. Bone specific surface (BsBv) was the only parameter that was underestimated by MRI. This underestimation, in combination with the overestimation of further parameters, is usually associated with a denser bone [ 4 ]. All di ff erences were statistically significant at p = 0.05. High statistical correlation (r = 0.826;
[[[ p. 5 ]]]
[Find the meaning and references behind the names: Ways, Human, Vary, Chosen, Fields, Read, Field, Inter, Main, Original, Future, Patient, Architecture, Simple, Knowledge, Author, Lower, Small, Bones, Shown, Look]
Int. J. Environ. Res. Public Health 2020 , 17 , 9282 5 of 7 p < 0.05) was found for BV measurements indicating a variance of r 2 = 0.683 ( p = 0.02) using linear-regression model y = 1.04 x + 0.30 4. Discussion MRI was proposed for dental-implant planning since it depicts accurately anatomical structures relevant for the surgical procedure. Previous studies focused on digital planning to determine the implant position, showing that the technique is capable of determining BV within clinical requirements [ 28 , 29 ]. However, to the authors’ knowledge, this is the first study using MRI to assess trabecular-bone morphology The findings of this study showed that MRI overestimated bone parameters when compared to the gold-standard µ CT. Thus, it can indicate that the bone is denser than it really is Nonetheless, especially‘bone-volume determination was highly correlated with the reference values Through mathematical formulation, it was possible to predict that, for each increase in CBCT-determined BV, an increase of 1.04 mm 3 occurred on the basis of T 1-weighted MRI. This linear relation explains 68.3% of the variation between groups Porcine ribs were chosen due to their similarity with the human maxillary bone [ 26 ]. However, these results must be interpreted with caution since bone anatomical variation and interference of the surrounding tissue on T 2 relaxation times were not considered. In addition, results may vary according to the scan protocol and the clinical situation. For instance, spatial resolution can a ff ect the visualization of anatomical structures [ 15 , 21 ]. Furthermore, artifacts provided from structures, as metallic restorations, dental implants, or the simple interface between air and mucosa [ 19 ], were not considered. Clinically, it is expected that other factors, such as patient movements, could a ff ect the image, resulting in lower image quality Thus, although these preliminary results can support the use of MRI to the understanding of bone architecture prior to implant placement, they cannot be applied to the clinical field. Further studies are required before drawing a conclusion regarding bone-quality assessment using MRI Although this analysis focused on dental-implant planning, where a three-dimensional bone evaluation is required [ 11 , 12 , 22 ], assessment of the bone microarchitecture is well-known in the medical literature. For instance, MRI was shown to be a technique for monitoring systemic bone diseases since it allows for recognizing changes on trabecular-bone morphology [ 21 ]. Thus, developing specific protocols for the monitoring of bone-remodeling processes could benefit di ff erent medical fields [ 30 , 31 ]. The main limitations of this methodology are the small sample size and the absence of inter-reliability analysis to validate the measurements. Future studies should include MRI assessment considering clinical conditions instead of porcine bones. Moreover, further analysis should be conducted to determine whether the bone-quality assessment corresponds with current bone classification. In summary, this initial study shows that the use of MRI for the assessment of the trabecular bone is possible, provided that an accurate and reliable MRI protocol is used. Future studies should look for ways to increase MRI spatial resolution while using a clinical setup and a higher sample size 5. Conclusions Within the limitations of this study, MRI overestimated trabecular-bone parameters, but with a statistically significant fixed linear o ff set. Further studies are required to determine the clinical feasibility of MRI for trabecular-bone assessment Author Contributions: Conceptualization, L.B., P.T., J.K., M.H.; methodology, L.B., F.G., N.M.; software, F.G.; validation, J.K., M.H.; formal analysis, L.B., P.T., J.K., M.H.; investigation; writing—original-draft preparation, L.B.; writing—review and editing, L.B., P.T., N.M., F.G., J.K., M.H. All authors have read and agreed to the published version of the manuscript Funding: This research received no external funding Conflicts of Interest: The authors declare no conflict of interest.
[[[ p. 6 ]]]
[Find the meaning and references behind the names: Van Dessel, De Oliveira, Flash, Jacobs, Jurczak, Maron, Kiani, Lindh, Alara, Stadelmann, Alloy, Redpath, Thomas, Whyte, Wanner, Clin, Morad, Single, Salmon, Cakmak, Golding, Bayrak, Puls, Thieme, Noise, Huang, Flugge, Head, Part, Daboul, Micro, Smith, Demirturk, Rotta, Gallucci, Eley, Ludwig, Heil, Orhan, Edwards, Dias, Mentor, Mertens, Hennig, Ribeiro, Kursun, Prager, Kim, Hard, Marotti, Med, Oxford, Chen, Case, Nelson, Ustaoglu, Black, Sta, Truong, Weber, Semin, Oliveira, Watt, Hammerle]
Int. J. Environ. Res. Public Health 2020 , 17 , 9282 6 of 7 References 1 Lekholm, U.; Zarb, G.A Tissue Integrated Protheses: Osseointegration in Clinical Dentistry ; Quintessence: Batavia, NY, USA, 1985 2 Oh, J.S.; Kim, S.G. Clinical study of the relationship between implant stability measurements using Periotest and Osstell mentor and bone quality assessment Oral Surg. Oral Med. Oral Pathol. Oral Radiol 2012 , 113 , 35–40. [ CrossRef ] [ PubMed ] 3 Ribeiro-Rotta, R.F.; de Oliveira, R.C.; Dias, D.R.; Lindh, C.; Leles, C.R. Bone tissue microarchitectural characteristics at dental implant sites part 2: Correlation with bone classification and primary stability Clin. Oral Implant. Res 2014 , 25 , 47–53. [ CrossRef ] [ PubMed ] 4 Van Dessel, J.; Nicolielo, L.F.; Huang, Y.; Coudyzer, W.; Salmon, B.; Lambrichts, I.; Jacobs, R. Accuracy and reliability of di ff erent cone beam computed tomography (CBCT) devices for structural analysis of alveolar bone in comparison with multislice CT and micro-CT Eur. J. Oral Implantol 2017 , 10 , 95–105. [ PubMed ] 5 Benic, G.I.; Mokti, M.; Chen, C.J.; Weber, H.P.; Hammerle, C.H.; Gallucci, G.O. Dimensions of buccal bone and mucosa at immediately placed implants after 7 years: A clinical and cone beam computed tomography study Clin. Oral Implant. Res 2012 , 23 , 560–566. [ CrossRef ] 6 Behnia, H.; Motamedian, S.R.; Kiani, M.T.; Morad, G.; Khojasteh, A. Accuracy and reliability of cone beam computed tomographic measurements of the bone labial and palatal to the maxillary anterior teeth Int. J Oral Maxillofac. Implant 2015 , 30 , 1249–1255. [ CrossRef ] 7 Bohner, L.O.L.; Tortamano, P.; Marotti, J. Accuracy of linear measurements around dental implants by means of cone beam computed tomography with di ff erent exposure parameters Dentomaxillofac. Radiol 2017 , 46 , 20160377. [ CrossRef ] 8 Hendee, W.R.; Edwards, F.M. ALARA and an integrated approach to radiation protection Semin. Nucl. Med 1986 , 16 , 142–150. [ CrossRef ] 9 Duttenhoefer, F.; Mertens, M.E.; Vizkelety, J.; Gremse, F.; Stadelmann, V.A.; Sauerbier, S. Magnetic resonance imaging in zirconia-based dental implantology Clin. Oral Implant. Res 2015 , 26 , 1195–1202. [ CrossRef ] 10 Fluegge, T.; Hovener, J.B.; Ludwig, U.; Eisenbeiss, A.K.; Spittau, B.; Hennig, J.; Schmelzeisen, R.; Nelson, K. Magnetic resonance imaging of intraoral hard and soft tissues using an intraoral coil and FLASH sequences Eur. Radiol 2016 , 26 , 4616–4623. [ CrossRef ] 11 Hilgenfeld, T.; Prager, M.; Schwindling, F.S.; Heil, A.; Kuchenbecker, S.; Rammelsberg, P.; Bendszus, M.; Heiland, S. Artefacts of implant-supported single crowns - Impact of material composition on artefact volume on dental MRI Eur. J. Oral Implantol 2016 , 9 , 301–318 12 Wanner, L.; Ludwig, U.; Hovener, J.B.; Nelson, K.; Flugge, T. Magnetic resonance imaging-a diagnostic tool for postoperative evaluation of dental implants: A case report Oral Surg. Oral Med. Oral Pathol. Oral Radiol 2018 , 125 , e 103–e 107. [ CrossRef ] [ PubMed ] 13 Demirturk Kocasarac, H.; Kursun-Cakmak, E.S.; Ustaoglu, G.; Bayrak, S.; Orhan, K.; Noujeim, M. Assessment of signal-to-noise ratio and contrast-to-noise ratio in 3 T magnetic resonance imaging in the presence of zirconium, titanium, and titanium-zirconium alloy implants Oral Surg. Oral Med. Oral Pathol. Oral Radiol 2020 , 129 , 80–86. [ CrossRef ] [ PubMed ] 14 Boeddinghaus, R.; Whyte, A. Trends in maxillofacial imaging Clin. Radiol 2018 , 73 , 4–18. [ CrossRef ] [ PubMed ] 15 Gray, C.F.; Redpath, T.W.; Smith, F.W.; Sta ff , R.T. Advanced imaging: Magnetic resonance imaging in implant dentistry Clin. Oral Implant. Res 2003 , 14 , 18–27. [ CrossRef ] [ PubMed ] 16 Bryll, A.; Urbanik, A.; Chrzan, R.; Jurczak, A.; Kwapinska, H.; Sobiecka, B. MRI disturbances caused by dental materials Neuroradiol. J 2007 , 20 , 9–17. [ CrossRef ] [ PubMed ] 17 Eley, K.A.; Watt-Smith, S.R.; Golding, S.J. “Black bone” MRI: A potential alternative to CT when imaging the head and neck: Report of eight clinical cases and review of the Oxford experience Br. J. Radiol 2012 , 85 , 1457–1464. [ CrossRef ] [ PubMed ] 18 Klinke, T.; Daboul, A.; Maron, J.; Gredes, T.; Puls, R.; Jaghsi, A.; Bi ff ar, R. Artifacts in magnetic resonance imaging and computed tomography caused by dental materials PLoS ONE 2012 , 7 , e 31766. [ CrossRef ] 19 Blankenstein, F.; Truong, B.T.; Thomas, A.; Thieme, N.; Zachriat, C. Predictability of magnetic susceptibility artifacts from metallic orthodontic appliances in magnetic resonance imaging J. Orofac. Orthop 2015 , 76 , 14–29. [ CrossRef ]
[[[ p. 7 ]]]
[Find the meaning and references behind the names: La Bruna, Di Carlo, De Angelis, Lammers, Cassetta, Angelis, Buchner, Song, Mayer, Schweiger, Basel, Marques, Zhao, Menzel, Fang, Shaheen, Sci, Ann, Galasso, Vivo, Maps, Carvalho, Cervino, Pauwels, Cavalcanti, Kiessling, Faul, Sutter, Pompa, Burian, Jungmann, Novel, Majumdar, Shujaat, Aguiar, Rat, Open, Roma, Link, Free, Carlo, Probst, Lang, Issever, Sambataro, Dent, Pre, Krug, Bruna]
Int. J. Environ. Res. Public Health 2020 , 17 , 9282 7 of 7 20 Blankenstein, F.H.; Asbach, P.; Beuer, F.; Glienke, J.; Mayer, S.; Zachriat, C. Magnetic permeability as a predictor of the artefact size caused by orthodontic appliances at 1.5 T magnetic resonance imaging Clin. Oral Investig 2017 , 21 , 281–289. [ CrossRef ] 21 Pompa, V.; Galasso, S.; Cassetta, M.; Pompa, G.; De Angelis, F.; Di Carlo, S. A comparative study of Magnetic Resonance (MR) and Computed Tomography (CT) in the pre-implant evaluation Ann. Stomatol. (Roma) 2010 , 1 , 33–38 22 Aguiar, M.F.; Marques, A.P.; Carvalho, A.C.; Cavalcanti, M.G. Accuracy of magnetic resonance imaging compared with computed tomography for implant planning Clin. Oral Implant. Res 2008 , 19 , 362–365 [ CrossRef ] [ PubMed ] 23 Jungmann, P.M.; Agten, C.A.; Pfirrmann, C.W.; Sutter, R. Advances in MRI around metal J. Magn. Reson Imaging 2017 , 46 , 972–991. [ CrossRef ] [ PubMed ] 24 Folkesson, J.; Krug, R.; Goldenstein, J.; Issever, A.S.; Fang, C.; Link, T.M.; Majumdar, S. Evaluation of correction methods for coil-induced intensity inhomogeneities and their influence on trabecular bone structure parameters from MR images Med. Phys 2009 , 36 , 1267–1274. [ CrossRef ] [ PubMed ] 25 Bohner, L.; Meier, N.; Gremse, F.; Tortamano, P.; Kleinheinz, J.; Hanisch, M. Magnetic resonance imaging artifacts produced by dental implants with di ff erent geometries Dentomaxillofac. Radiol 2020 , 49 , 20200121 [ CrossRef ] [ PubMed ] 26 Faul, F.; Erdfelder, E.; Lang, A.G.; Buchner, A. G*Power 3: A flexible statistical power analysis program for the social, behavioral, and biomedical sciences Behav. Res. Methods 2007 , 39 , 175–191. [ CrossRef ] [ PubMed ] 27 Gremse, F.; Stärk, M.; Ehling, J.; Menzel, J.R.; Lammers, T.; Kiessling, F. Imalytics Preclinical: Interactive Analysis of Biomedical Volume Data Theranostics 2016 , 6 , 328–341. [ CrossRef ] [ PubMed ] 28 Probst, F.A.; Schweiger, J.; Stumbaum, M.J.; Karampinos, D.; Burian, E.; Probst, M. Magnetic resonance imaging based computer-guided dental implant surgery—A clinical pilot study Clin. Oral Implant. Res 2020 , 22 , 612–621. [ CrossRef ] 29 Hilgenfeld, T.; Juerchott, A.; Jende, J.M.; Rammelsberg, P.; Heiland, S.; Bendszus, M.; Schwindling, F.S. Use of dental MRI for radiation-free guided dental implant planning: A prospective, in vivo study of accuracy and reliability Eur. Radiol 2020 , 30 , 6392–6401. [ CrossRef ] 30 Sambataro, S.; Cervino, G.; Bocchieri, S.; La Bruna, R.; Cicciu, M. TMJ dysfunctions systemic implications and postural assessments. A review of recent literature J. Funct. Morphol. Kinesiol 2019 , 4 , 58. [ CrossRef ] 31 Song, D.; Shujaat, S.; Zhao, R.; Huang, Y.; Shaheen, E.; Van Dessel, J.; Orhan, K.; Coropciuc, R.; Pauwels, R.; Vande Velde, G.; et al. In vivo quantification of mandibular bone remodeling and vascular changes in a Wistar rat model: A novel HR-MRI and micro-CT fusion technique Imaging Sci. Dent 2020 , 50 , 199–208 [ CrossRef ] Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional a ffi liations © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http: // creativecommons.org / licenses / by / 4.0 / ).